Modell: Gale Series
Verkaufseinheiten | : | Others |
---|
● Schlüsselkomponente
● COP -Diagramm
● Installation
● Eingebaute Wasserpumpe
Model: NE-F |
30HWR3 |
40HWR3 |
60HWR3 |
85HWR3 |
*Test Condition: Ambient Temperature: (DB/WB) 20°C / 15°C Water temperature from 15°C to 55°C. |
||||
Rated Heating Capacity (kW) |
3.1 | 4.1 | 5.8 | 8.5 |
Consumed Power(kW)
|
0.794 | 1.05 | 1.487 | 2.42 |
COP |
3.90 | 3.90 | 3.90 | 3.51 |
Max. Power Input(kW) |
1.21 | 1.738 | 2.57 | 3.498 |
Max. Running Current (A) |
5.5 | 7.9 | 11.7 | 15.9 |
Hot Water Volume (L/h) |
66 |
88 |
124 |
182 |
Water Flow Volume(m³ /h) |
0.53 | 0.705 | 1 | 1.46 |
Water Pressure Drop(kPa) |
30 | 30 | 30 | 45 |
Water Connection |
G3/4"(female) |
|||
Sound Pressure at 1m dB(A) |
≤51 |
≤51 |
≤54 |
≤58 |
Power Supply(V/Ph/Hz) |
220-240V~/ 50Hz |
|||
Operation Temp. Range(℃) |
-7 ~ 43 |
|||
Max. Outlet Water Temperature(℃)
|
60 | |||
Refrigerant Type |
R410A |
|||
Net Dimensions(L/W/H)(mm) |
768x298x476 |
898x366x525 |
994x366x525 |
1060x366x599 |
Notice : The above data is for reference only, the specific data is subject to actual product. |